Rockwell Automation 198x Modular DeviceNet Starter Auxiliary I/O User Manual
Page 75
Specifications 5-9
Publication 198-UM001B-EN-P September 2001
➊ These specifications are for reference only. Refer to sensor specification for exact values.
Table 5.F 198-IB2S Specifications
Connector (M12 Female 5-Pin)
M12 Mounting Hole
16 mm (5/8 in.) M12
M12 Thread
M12 x 1 mm
M12 Connector Torque
1.4 Nm (12 lb-in.)
Electrical
Module Voltage Rating
24V DC
Module Operating Voltage Range
11…25V DC
Module Current Draw w/o Sensor
26 mA @ 24V DC
Input Voltage Rating
24V DC
Input On-State Voltage
10…26V DC
Input On-State Current
3.0 mA @ 10V DC
7.2 mA @ 24V DC
Input Off-State Voltage
0…5V DC
Input Off-State Current
< 1.5 mA
Short Circuit Detect Level
< 2V DC
Open Circuit Detect Level
< 100
µA
Module Isolation
Non-isolated mis-wire protected
Input Filter — Software
Selectable (with two I/O modules)
Off to On
1, 2, 4, 8, 16 ms
On to Off
1.3, 2, 4, 8, 16 ms
Input Compatibility
IEC 1+
Sensor
Sensor Operating Voltage
Typ. 3-wire
➊
11…25V DC
Typ. 2-wire
18…25V DC
Sensor Current Draw Max.
➊
100 mA
Environmental
Ambient Temperature
Operating
–25…+60°C (–4…+140°F)
Storage
–40…+85°C (–40…+185°F)
Relative Humidity
0…95% non-condensing
Shock
Operating
30 g peak acceleration
Non-Operating
50 g peak acceleration
Operating Vibration
10 g @ 58…2000 Hz
0.060 in. peak-to-peak displacement 2…57 Hz
Per IEC 68-2-6
Approvals
Agency Certification
(when product is marked)
cUL
UL Listed
CE marked for all applicable directives