Assembly object— class id (04hex), Assembly object — class id (04hex) – Rockwell Automation 198x Modular DeviceNet Starter Auxiliary I/O User Manual
Page 147

DeviceNet Information A-7
Publication 198-UM001B-EN-P September 2001
The following services are implemented for the DeviceNet Object:
Assembly Object — Class ID (04hex)
The Modular-DSA I/O System can send and receive data in a variety of formats. Some
formats are made to facilitate off-line programming, while others minimize the amount of
data transmitted back to the host. Each type of data formatting, or assembly, is referred to as
an instance. Assemblies are referenced from the master’s (usually a PLC) perspective. The
Output Assembly is data sent by a master and received by the Modular-DSA I/O System
modules. An Input Assembly is the data sent by a Modular-DSA I/O System device and
received by a master. The following is a list of all of the different assemblies. An explanation
for each follows the tables.
Table A.7 DeviceNet Object Common Services
Service Code
Implemented for:
Service Name
Class
Instance
0x0E
Yes
Yes
Get_Attribute_Single
0x10
No
Yes
Set_Attribute_Single
0x4B
No
Yes
Allocate_Master/Slave_Connection_Set
0x4C
No
Yes
Release_Master/Slave_Connection_Set
Table A.8 Output Assemblies
Assembly No.
Assembly
Size
Comment
100
Variable
Available for 198-DN/DNG (series A and B)
102
Variable
One byte per module output data (available for series B 198-DN/DNG)
104
6 bytes
Default for series B 198-DNG (available for series B 198-DNG only)
106
16 bytes
Default for series B 198-DN (available for series B 198-DN only)
Table A.9 Input Assemblies
Assembly No.
Assembly
Size
Comment
101
Variable
Compressed Assemblies (available for 198-DN/DNG — series A and B)
103
Variable
One byte per module input data (available for series B 198-DN/DNG)
105
8 bytes
Default for series B 198-DNG (available for series B 198-DNG only)
107
20 bytes
Default for series B 198-DN (available for series B 198-DN only)