beautypg.com

Header operation – a series, 4 reel speed – MacDon M100 SP Operators Manual User Manual

Page 97

background image

HEADER OPERATION – A SERIES

169304

95

Rev. C

6.6.4 Reel

Speed

6.6.4.1 A30-S and A30-D Headers

The reel speed is fixed to the auger speed and
to the knife speed. Both can be changed by
installing alternate drive sprockets. Refer to
your Auger Header Operator’s Manual.

6.6.4.2 A40-D

Header

The A40-D auger header features a hydraulic
direct drive reel with operating speed range of
51 to 76 rpm and is controlled with switches on
the CDM, and on the GSL at the operator’s
station. The hydraulic flows for the reel and
auger are interconnected so that the auger and
reel speeds are controlled using a combination
of the CDM switches and the GSL switches.

ENGAGE HEADER

ON CDM PRESS

FAST

DISPLAY SHOWS

##.# AUGER SPEED

DONE

SPEED

99.0?

NO

YES

PRESS

DISPLAY SELECTOR

FOR

##.# AUGER SPEED

HEADER INDEX

SWITCH -

OFF

##.# = 0.00 – 9.9

00.0 = 150 rpm

* 9.9 = 320 rpm

* Auger Speed Not To Exceed 320 rpm.

ON GSL PRESS

FAST OR SLOW

DISPLAY SHOWS

##.## REEL SPEED

SPEED

OK?

NO

YES

PRESS

DISPLAY SELECTOR

FOR

##.## REEL SPEED

SPEED

OK?

NO

YES

##.## = RPM

DISPLAY
SELECTOR

DISPLAY

HEADER INDEX

FAST

SLOW

AUGER & REEL SPEED

SLOW

FAST

REEL SPEED