Caution, Header operation – d series – MacDon M100 SP Operators Manual User Manual
Page 86
![background image](/manuals/570513/86/background.png)
HEADER OPERATION – D SERIES
169304
84
Rev. C
Example:
Windrower is operating at 8 mph with Header
Index on and set at 5.5. Display shows;
13.5 5.5 REEL IND
where
13.5 (8+5.5) is the reel speed in mph, and
5.5 is the header index setting.
Windrower speed drops to 7.5 mph at same
Header Index setting. Display shows;
13.0 5.5 REEL IND
where
13.0 (7.5+5.5) is the reel speed in mph,
and
5.5 is the header index setting.
Windrower is operating at 8 mph with Header
Index on and set at 1.0. Display shows;
9.0 1.0 REEL IND
where
9.0 (8+1.0) is the reel speed in mph, and
1.0 is the header index setting.
6.5.6.2
Reel Only Speed
Set the reel speed independently of ground
speed as follows:
CAUTION
Check to be sure all bystanders have cleared
the area.
NOTE
This procedure can also be used to
change the draper speed “on the go”.
These changes become the new set-
points.
##.## = MPH or KPH
ENGAGE HEADER
HEADER INDEX
SWITCH -
OFF
ON GSL PRESS REEL SPEED
SWITCH
FAST OR SLOW
DISPLAY SHOWS
##.## REEL MPH
DONE
SPEED
O.K.?
NO
YES
DISPLAY
SELECTOR
DISPLAY
HEADER INDEX
FAST
SLOW