Electrical installation

Installation according to EMC (installation of a CE−typical drive system)
Shielding

6

l

92

EDS700ACBA EN 4.0

Realisation

i700EMV001 a

i700EMV001 b

Fig. 6−1

Wiring in compliance with EMC standards

0

Mounting plate with electrically conductive surface

1

Earth connection of the control cabinet elements

2

Mains connection, unshielded cable

3

Bundling of cables in the conduit

4

Control cables and supply voltage, unshielded

5

System cables, EtherCAT® communication bus (scope of supply)

6

System cable for feedback, servo control

"

Integrated shield connection (functional earth) with shield clamp (scope of supply)

7

Shielded cables of the motor, motor holding brake and brake resistor connections
Motor cable, shielded, low−capacitance (see also technical data, page 28)
£ 2.5 mm

2

(AWG 14): Core/core

£ 75 pF/m; core/shield £ 150 pF/m

³ 4.0 mm

2

(AWG 12): Core/core

£ 150 pF/m; core/shield £ 300 pF/m

+