Dc−bus operation, Rated data dc−supply power, 400 v – Lenze i700 Manual User Manual
Page 114: 480 v

DC−bus operation
Rated data
DC−supply power
l
114
EDS700ACBA EN 4.0
400 V
Power supply U
Lr
= 400 V
Cycle 1
Cycle 2
Type
P
DC 100%
[kW]
P
ol
· t
ol
[kW] · [s]
P
re
· t
re
[kW] · [s]
P
ol
· t
ol
[kW] · [s]
P
re
· t
re
[kW] · [s]
Supply modules (+ filter)
E70ACPSx0304x
10.3
20.6 · 3
6.8 · 12
15.5 · 60
7.7 · 120
E70ACPSx0304x
+ E94AZMP0084
E70ACPSx0304x
+ E94AZMP0294
15.4
30.8 · 3
10.2· 12
23.1 · 60
11.6 · 120
E70ACPSx0604x
20.6
41.2 · 3
13.6· 12
30.9 · 60
15.5 · 120
E70ACPSx0604x
+ E94AZMP0824
30.9
61.8 · 3
20.4· 12
46.4 · 60
23.2 · 120
Regenerative power supply modules + filters
E94ARNE0134
+ E94AZMR0264xDB
15.0
44.9 · 3
11.3· 12
22.4 · 60
11.3 · 120
E94ARNE0244
+ E94AZMR0474xDB
27.0
81.1 · 3
20.3· 12
43 · 60
20.3 · 120
Tab. 7−2
480 V
Power supply U
Lr
= 480 V
Cycle 1
Cycle 2
Type
P
DC 100%
[kW]
P
ol
· t
ol
[kW] · [s]
P
re
· t
re
[kW] · [s]
P
ol
· t
ol
[kW] · [s]
P
re
· t
re
[kW] · [s]
Supply modules (+ filter)
E70ACPSx0304x
12.3
24.6 · 3
8.1 · 12
18.5 · 60
9.2 · 120
E70ACPSx0304x
+ E94AZMP0084
E70ACPSx0304x
+ E94AZMP0294
18.5
37.0 · 3
12.2· 12
27.8 · 60
13.9 · 120
E70ACPSx0604x
24.7
49.4 · 3
16.3· 12
37.1 · 60
18.5 · 120
E70ACPSx0604S
+ E94AZMP0824
37.0
74.0 · 3
24.4· 12
55.5 · 60
27.8 · 120
Regenerative power supply modules + filters
E94ARNE0134
+ E94AZMR0264xDB
18.6
56.1 · 3
14.0 · 12
28.0 · 60
14.0 · 120
E94ARNE0244
+ E94AZMR0474xDB
33.8
101.4 · 3
25.4 · 12
50.7 · 60
25.4 · 120
Tab. 7−3