Led status displays, Supply modules, Axis modules – Lenze i700 Manual User Manual
Page 125: Diagnostics

Diagnostics
LED status displays
Supply modules
l
125
EDS700ACBA EN 4.0
9.2
LED status displays
9.2.1
Supply modules
LED display of power supply module − V100
Colour
Name
Status
Description
blue
RDY
off
24−V supply voltage off or
£ 18 V
is ON
24−V supply voltage ok, module ready for operation
red
ERR
off
Power supply module ready for operation
is ON
Error/fault
9.2.2
Axis modules
LED display of axis module − V101
Colour
Name
Status
Description
blue
RDY
off
24−V supply voltage off or
£ 18 V
is ON
24−V supply voltage ok, module ready for operation
blinking
Axis module inhibited
fast blinking
Optical device identification (simultaneously with red/ERR)
red
ERR
off
Axis module ready for operation − no error − axis A (and B)
is ON
Error/fault − device
Error/fault − axis A (or B)
fast blinking
Optical device identification (simultaneously with blue/RDY)
i700AX045 b
LED display of axis module − X4/X5 EtherCAT IN/OUT
Name
Status
Description
RUN
is ON
"Operational" status is active.
flickering
"Bootstrap" status is active.
blinking
"Pre−operational" status is active.
blinking once
(single flash)
"Safe−operational" status is active.
off
Fieldbus communication is not active or is in the "Init" state.
L/A
is ON
Physical EtherCAT connection is available.
flickering
Data are exchanged via EtherCAT.
off
Physical EtherCAT−CAT connection is not available
−
This LED is used for internal diagnostic purposes.