DC−bus variants

Supply with power supply modules operated in parallel

7

l

111

EDS700ACBA EN 4.0

7.3.2

Supply with power supply modules operated in parallel

L2

L1

L3

M

M

M

3

M

...

AC

V1

G1

Gx

L2

L1

L3

3

V2

V1

AC

i700ARPRx

AC

AC mains

V1, V2

Power supply modules

G1 ... Gx

Controllers

Power supply modules can be operated in parallel in order to increase the DC supply power
and/or the braking power.

For the central connection of power supply modules operated in parallel to the AC mains,
the filters must be dimensioned as collective filters.

Components to be used

i700 device series

Other device series

DC supply

Power supply modules

E70ACPSx0304x (30 A)

E70ACPSx0604x (60 A)

Mains chokes

EZAELN3025B122
EZAELN3050B591

Filter

RFI filters

Mains filters

E94AZMP0084
E94AZMP0294
E94AZMP0824

Interconnected device

Controllers

E70ACM...1... (single axis)

E70ACM...2... (double axis)