beautypg.com

Technical data, Terminal description supply modules, External voltage supply – Lenze i700 Manual User Manual

Page 44

background image

Technical data

Terminal description
Supply modules

4

l

44

EDS700ACBA EN 4.0

External voltage supply

X21

Labelling

Description

24E

24−V supply voltage of control electronics from a safely separated
power supply unit (SELV/PELV)

GE

Reference potential (GND)

i700PX021

Terminal data

Conductor cross−section

Tightening torque

!

[mm

2

]

[AWG]

[Nm]

[lb−in]

flexible

0.2 ... 2.5

24 ... 12

3.5 x 0.6

X21 Electrical data

24E
GE

Rated voltage

24 V

in accordance with
IEC 61131−2

Voltage range

19.2 ... 28.8 V

Residual ripple

Max.

± 5 %

Current consumption

See technical data,

^ 4.2.1

Polarity reversal
protection

When polarity is reversed: no function and no
destruction.

Cable protection

Circuit breaker with tripping characteristic B or C
Standard blade−type fuses

X21, X3

X21

DC 24 V

(+19.2...+28.8 V)

GND-I

GE 24E

i700M00x

Fig. 1

Wiring of X21

X21

Connection of the control electronics supply voltage at the power supply
module, can be looped through to other power supply or axis modules

24E

DC 24 V, acc. to IEC IEc 61131−2, SELV/PELV

GE

Reference potential GND