Accessories (overview)

RFI filter/mains filter

11

l

140

EDS700ACBA EN 4.0

11.3

RFI filter/mains filter

Advantages by the use of filters:

ƒ

Compliance with EMC requirements

ƒ

Reduction of the current load

ƒ

Positive effects on the service life of the controllers possible
– Strong reliability
– Reduction of the failure rate

ƒ

Operation on 30 mA residual−current circuit breakers for device sizes 1 ... 3 (up to
24 A/11 kW) is enabled.

Mains filters:
Mains filters reduce the conducted interference emission into the mains for compliance
with the requirements acc. to EN 61800−3. Mains filters are a combination of mains choke
and RFI filter in one housing.

Voltage

Freq.

Current [A]

Current [A]

Number of

phases

[V]

[Hz]

 max. +45° C

 max. +55° C

E94AZMP0084

400/480

50/60

8/8

6/6

3

E94AZMP0294

400/480

50/60

29/29

21.8/21.8

3

E94AZMP0824

400/480

50/60

82/82

61/61

3

 Temperature in the control cabinet

RFI filters:
RFI filters are capacitive accessories for compliance with the requirements acc. to
EN 61800−3 for conducted interference emission. RFI filters can be directly connected
upstream of the power supply modules. RFI filters are also called EMC filters.

Voltage

Freq.

Current [A]

Current [A]

Number of

phases

[V]

[Hz]

 max. +45° C

 max. +55° C

E94AZRP0084

400/480

50/60

8/8

6/6

3

E94AZRP0294

400/480

50/60

29/29

21.8/21.8

3

E94AZRP0824

400/480

50/60

82/82

61/61

3

 Temperature in the control cabinet