beautypg.com

Technical data, Terminal description axis modules, Digital inputs – Lenze i700 Manual User Manual

Page 51

background image

Technical data

Terminal description

Axis modules

4

l

51

EDS700ACBA EN 4.0

Digital inputs

X2

Labelling

Description

DI1

Touch probe inputs

On double axis devices, there are
two of these connections. For the
assignment to the axes, the
designations "A" / "B" are used.

DI2

GD

Reference potential GND

i700P00x

Terminal data

Conductor cross−section

Tightening torque

!

[mm

2

]

[AWG]

[Nm]

[lb−in]

flexible

0.2 ... 2.5

24 ... 12

3.5 x 0.6

X2

Electrical data

DI1
DI2

Rated voltage

24 V

in accordance with
IEC 61131−2

Voltage range

19.2 ... 28.8 V

Residual ripple

Max.

± 5 %

Current consumption

Max. 8 mA

Polarity reversal
protection

When polarity is reversed: no function and no
destruction.

GD

Reference potential

0 V

DI1

DI2

GD

B

DC 24 V

(+19.2...
+28.8 V)

DI1

DI2

GD

A

X2

i700M00x

Fig. 5

Wiring of X2

X2

Connection of digital inputs of axis module

A

1−axis module

B

Additionally for 2−axis module

DIx

Digital input

GD

Reference potential GND