beautypg.com

Technical data – Lenze i700 Manual User Manual

Page 26

background image

Technical data

General data and operating conditions

4

l

26

EDS700ACBA EN 4.0

EMC
Operation in industrial
environment

EN 61000−3

The devices are intended for use in an industrial
environment.
A drive system consisting of a power supply module and 6
axis modules (each with a motor cable length of 25m)
complies with EMC class „C3ˆ without any external
measures.
When third party power supply modules, power supply
modules connected in parallel or longer motor cable lengths
are used, matching mains filters must be installed to comply
with the EMC requirements.

The compliance with the requirements for the
machine/plant is the responsibility of the manufacturer of
the machine or system!

Operation on public supply
systems

EN 61000−3

When being used on public network, additional measures
must be taken to limit the expected radio interference.

Noise emission

Cable−guided

EN 61800−3

Depending on the filter at the central power supply module

Radiation

EN 61800−3

Single components of the i700 series:

l

Category C3

Noise immunity (according to requirements of EN 61800−3)

Electrostatic discharge
(ESD)

EN 61000−4−2

8 kV for air discharge to control cabinet,
4 kV for contact discharge to housing

Radio frequency

Cable−guided

EN 61000−4−6

150 kHz ... 80 MHz, 10 V/m 80 % AM (1kHz)

Interference (housing) EN 61000−4−3

80 MHz ... 1000 MHz, 10 V/m 80 % AM (1kHz)
1.4 GHz ... 2 GHz, 3 V/m 80 % AM (1kHz)
2 GHz ... 2.7 GHz, 1 V/m 80 % AM (1kHz)

Burst

Power terminals and
interfaces

EN 61000−4−4

2 kV/5 kHz

Signal interfaces

EN 61000−4−4

1 kV/5 kHz

Control terminals

EN 61000−4−4

2 kV/5 kHz

Surge

Power terminals

EN 61000−4−5

1.2/50

ms,

1 kV phase/phase, 2 kV phase/PE

Control terminals

EN 61000−4−5

1.2/50

ms, 1 kV