Technical data – Lenze i700 Manual User Manual
Page 26

Technical data
General data and operating conditions
l
26
EDS700ACBA EN 4.0
EMC
Operation in industrial
environment
EN 61000−3
The devices are intended for use in an industrial
environment.
A drive system consisting of a power supply module and 6
axis modules (each with a motor cable length of 25m)
complies with EMC class C3ˆ without any external
measures.
When third party power supply modules, power supply
modules connected in parallel or longer motor cable lengths
are used, matching mains filters must be installed to comply
with the EMC requirements.
The compliance with the requirements for the
machine/plant is the responsibility of the manufacturer of
the machine or system!
Operation on public supply
systems
EN 61000−3
When being used on public network, additional measures
must be taken to limit the expected radio interference.
Noise emission
Cable−guided
EN 61800−3
Depending on the filter at the central power supply module
Radiation
EN 61800−3
Single components of the i700 series:
l
Category C3
Noise immunity (according to requirements of EN 61800−3)
Electrostatic discharge
(ESD)
EN 61000−4−2
8 kV for air discharge to control cabinet,
4 kV for contact discharge to housing
Radio frequency
Cable−guided
EN 61000−4−6
150 kHz ... 80 MHz, 10 V/m 80 % AM (1kHz)
Interference (housing) EN 61000−4−3
80 MHz ... 1000 MHz, 10 V/m 80 % AM (1kHz)
1.4 GHz ... 2 GHz, 3 V/m 80 % AM (1kHz)
2 GHz ... 2.7 GHz, 1 V/m 80 % AM (1kHz)
Burst
Power terminals and
interfaces
EN 61000−4−4
2 kV/5 kHz
Signal interfaces
EN 61000−4−4
1 kV/5 kHz
Control terminals
EN 61000−4−4
2 kV/5 kHz
Surge
Power terminals
EN 61000−4−5
1.2/50
ms,
1 kV phase/phase, 2 kV phase/PE
Control terminals
EN 61000−4−5
1.2/50
ms, 1 kV