background image

DC−bus operation

DC−bus variants
Supply with regenerative power supply module

7

l

112

EDS700ACBA EN 4.0

7.3.3

Supply with regenerative power supply module

L2

L2

L2.1

L1

L1

L1.1

L3

L3

L3.1

M

M

M

3

3

M

...

~ =

AC

VR1

Z1

G1

Gx

AC

AC mains

Z1

Regenerative power supply filter

VR1

Regenerative power supply module

G1 ... Gx

Controllers

If the regenerative energy produced by a drive system is to be fed back to the AC mains, a
regenerative power supply module of the "Servo Drives 9400" device series can be used. A
brake chopper, to which a brake resistor can be connected, is integrated.

Components to be used

i700 device series

Other device series

DC supply

Regenerative power supply modules

E94ARNE0xx4 + E94AZMR0xx4xDB (13 ... 24 A)

Filter

− assigned to the regenerative power supply module

Interconnected device

Controllers

E70ACM...1... (single axis)

E70ACM...2... (double axis)