beautypg.com

Technical data, Terminal description axis modules – Lenze i700 Manual User Manual

Page 61

background image

Technical data

Terminal description

Axis modules

4

l

61

EDS700ACBA EN 4.0

X106

Labelling

Description

BD1

Motor holding brake
(+)

On double axis devices, there are
two of these connections. For the
assignment to the axes, the
designations "A" / "B" are used.

BD2

(−)

i700P00x

Terminal data

Conductor cross−section

Tightening torque

!

[mm

2

]

[AWG]

[Nm]

[lb−in]

flexible

0.2 ... 1.5

24 ... 16

3.5 x 0.6

X106 Electrical data

BD1
BD2

Voltage

24 V

Voltage range

Depending on the external voltage source for
controlling the brake(s)

Current consumption

Corresponding to the connected brake

Polarity reversal
protection

Not relevant

X106

Maximum switchable current for connected brakes

[A]

E70ACMSx0054xx1xxx
E70ACMSx0104xx1xxx
E70ACMSx0204xx1xxx

1.5

E70ACMSx0054xx2xxx
E70ACMSx0104xx2xxx
E70ACMSx0204xx2xxx

2 x 1.5

E70ACMSx0324xx1xxx
E70ACMSx0484xx1xxx
E70ACMSx0644xx1xxx

2.5

E70ACMSx0324xx2xxx

2 x 2.5

"

M

BD1

BD2

B

"

M

A

BD1

BD2

X106

"

"

i700M00x

Fig. 8

Wiring of X106

X106

Connection of a motor holding brake

A, B

A: 1−axis module, B: additionally for 2−axis module

BD1, BD2

Coil voltage 24 V DC
(observe correct polarity for permanent magnet brakes)

"

Functional earth

", shield connection