beautypg.com

Technical data, Terminal description axis modules, Resolver – Lenze i700 Manual User Manual

Page 55

background image

Technical data

Terminal description

Axis modules

4

l

55

EDS700ACBA EN 4.0

Resolver

X7

Pin

Description

E70ACM...R

1

+REF

On single axis devices, this
connection is located on the
right−hand side below the labelling
"X7".

2

−REF

3

n. c.

4

+COS

5

−COS

6

+SIN

On double axis devices, there are two
of these connections. For the
assignment to the axes, the
designations "A" / "B" are used.

7

−SIN

8

+KTY

9

−KTY

"

Shield connection at Sub−D housing

i700AX007 a b

X7

Electrical data

General

Cable length (system cable is recommended)

Max. 50 m

3

n. c.

1, 2

+REF, −REF

Input frequency

max. 250 kHz

4, 5

+COS, −COS

Excitation voltage

10 V

SS

6, 7

+SIN, −SIN

Carrier frequency

4 kHz, constant value

8, 9

+KTY, −KTY

Type

KTY 83−110