Technical data, General data and operating conditions, 4technical data – Lenze i700 Manual User Manual
Page 25: 1 general data and operating conditions
Technical data
General data and operating conditions
4
l
25
EDS700ACBA EN 4.0
4
Technical data
4.1
General data and operating conditions
Conformity and approval
Conformity
CE
2006/95/EC
Low−Voltage Directive
2004/108/EC
EMC Directive
Machinery Directive
2006/42/EC
Logic unit to ensure safety functions
(safety component acc. to Machinery Directive)
EAC
TP TC 004/2011
(TR CU 004/2011)
On safety of low voltage
equipment
Eurasian Conformity
TR CU: Technical
Regulation of Customs
Union
TP TC 020/2011
(TR CU 020/2011)
Electromagnetic compatibility of
technical means
Approval
C
UL
US
UL 508C
CSA 22.2 No. 14
E70ACxSE...
Industrial Control
Equipment, Lenze File
No. 132659
C
UR
US
E70ACxSC...
E70ACxSD...
Protection of persons and devices
Enclosure
EN 60529
IP 20
Specification
l
applies to the fully
assembled state ready
for use
l
does not apply to the
wire range of the
terminals
UL
Protection against contact in
accordance with Open Type
EN 60529
Mounting type "push−through technique", heatsink side:
l
IP54
Insulation resistance
EN 61800−5−1
< 2000 m amsl: overvoltage category III
> 2000 m amsl: overvoltage category II
Insulation of control
circuits
EN 61800−5−1
Safe mains isolation through double/reinforced insulation
(
^ 6.1.1):
l
Touch probe inputs
l
Safety system inputs
l
Encoder feedback (
^ 54)
Short−circuit strength
EN 61800−5−1
l
Motor connection: limited, controller is inhibited, error
acknowledgement is required
l
Brake control: limited, error acknowledgement is required
l
Control electronics and holding brake supply connections:
not short−circuit−proof
Protective measures
integrated for
l
Short circuit
l
Earth fault
l
Overvoltage
l
Motor overload (temperature detection via encoder, I
2
t
monitoring)
Contact current
EN 61800−5−1
> 3.5 mA AC, > 10 mA DC
Observe the regulations
and safety instructions!
mains switching
Cyclic mains switching of 5 times in 5 minutes is permissible
without restrictions.
Starting current
£ 2 x I
rated
Discharge time of charge
stored after mains
disconnection
typically 5 min
The duration is indicated by a warning symbol on the device.