Technical data

General data and operating conditions

4

l

25

EDS700ACBA EN 4.0

4

Technical data

4.1

General data and operating conditions

Conformity and approval

Conformity

CE

2006/95/EC

Low−Voltage Directive

2004/108/EC

EMC Directive

Machinery Directive

2006/42/EC

Logic unit to ensure safety functions
(safety component acc. to Machinery Directive)

EAC

TP TC 004/2011
(TR CU 004/2011)

On safety of low voltage
equipment

Eurasian Conformity
TR CU: Technical
Regulation of Customs
Union

TP TC 020/2011
(TR CU 020/2011)

Electromagnetic compatibility of
technical means

Approval

C

UL

US

UL 508C
CSA 22.2 No. 14

E70ACxSE...

Industrial Control
Equipment, Lenze File
No. 132659

C

UR

US

E70ACxSC...
E70ACxSD...

Protection of persons and devices

Enclosure

EN 60529

IP 20

Specification

l

applies to the fully
assembled state ready
for use

l

does not apply to the
wire range of the
terminals

UL

Protection against contact in
accordance with Open Type

EN 60529

Mounting type "push−through technique", heatsink side:

l

IP54

Insulation resistance

EN 61800−5−1

< 2000 m amsl: overvoltage category III

> 2000 m amsl: overvoltage category II

Insulation of control
circuits

EN 61800−5−1

Safe mains isolation through double/reinforced insulation
(

^ 6.1.1):

l

Touch probe inputs

l

Safety system inputs

l

Encoder feedback (

^ 54)

Short−circuit strength

EN 61800−5−1

l

Motor connection: limited, controller is inhibited, error
acknowledgement is required

l

Brake control: limited, error acknowledgement is required

l

Control electronics and holding brake supply connections:
not short−circuit−proof

Protective measures
integrated for

l

Short circuit

l

Earth fault

l

Overvoltage

l

Motor overload (temperature detection via encoder, I

2

t

monitoring)

Contact current

EN 61800−5−1

> 3.5 mA AC, > 10 mA DC

Observe the regulations
and safety instructions!

mains switching

Cyclic mains switching of 5 times in 5 minutes is permissible
without restrictions.

Starting current

£ 2 x I

rated

Discharge time of charge
stored after mains
disconnection

typically 5 min