Mechanical installation – Lenze i700 Manual User Manual
Page 79

Mechanical installation
Notes on mounting the device version in push−through design
Assembly in push−through technique (thermal separation)
l
79
EDS700ACBA EN 4.0
Cooling by forced ventilation
Required:
ƒ
Forced ventilation by one or several fans.
ƒ
Air speed: 2.5 m/s at the MP measuring point
– For fan dimensioning: Corresponds to a volume flow of 0.5 m
3
/min (17.6 CFM) per
50 mm device installation width.
Permissible:
ƒ
Operation with continuous output current I
a
= I
rated
.
ƒ
Operation according to rated data.
ƒ
Switching frequencies f
ch
: 4 kHz, 8 kHz and 16 kHz
Cooling by means of natural convection
Required:
ƒ
Unhindered ventilation by means of natural convection (no fan required).
ƒ
Ambient temperature: T
amb
< 40 °C
Permissible:
ƒ
Operation with reduced output current I
a
according to Tab. 5−2.
ƒ
Switching frequencies f
ch
= 4 kHz and 8 kHz
Type
I
a
[A]
E70ACPxD0304x
25
E70ACPxD0604x
50
I
a
[A]
Type
4 kHz
8 kHz
16 kHz
E70ACMxD0054xx1ETx
2.5
2.5
−
E70ACMxD0104xx1ETx
5.0
5.0
E70ACMxD0204xx1ETx
6.0
6.0
E70ACMxD0054xx2ETx
2 x 2.5
2 x 2.5
E70ACMxD0104xx2ETx
S 5.0
S 5.0
E70ACMxD0324xx1ETx
12.0
9.6
E70ACMxD0484xx1ETx
14.0
11.2
E70ACMxD0644xx1ETx
16.0
12.8
E70ACMxD0204xx2ETx
S 10.0
S 10.0
E70ACMxD0324xx2ETx
S 12.0
S 9.6
Tab. 5−2
Permissible currents I
a
in case of natural convection
S Sum of the output currents axis A and axis B