beautypg.com

Basic dimensioning, General information, Dc−bus operation – Lenze i700 Manual User Manual

Page 116: Basic dimensioning general information

background image

DC−bus operation

Basic dimensioning
General information

7

l

116

EDS700ACBA EN 4.0

7.5

Basic dimensioning

7.5.1

General information

The Drive Solution Designer (DSD) PC software helps you to dimension your drive network.

For expert advice, you may also contact your Lenze sales representative when
dimensioning your application.

Time/performance diagram

For determining the performance of your drive network, create a time/performance
diagram for all axes for a complete machine cycle. The power requirements of the drive
network are calculated by adding the individual performances occurring at the same time.
Positive results show the AC requirements for the dimensioning of the power supply units.
Negative results show the brake power to be dissipated via brake choppers at the brake
resistor.

0

P

3

0

P

2

0

P

1

12

13

11

1

2

3

4

5

6

7

8

9

10

t

0

P

res

t

0

P

4

13

11

1

2

3

4

5

6

7

8

9

10

12

P

res

T/P−diag001

Fig. 7−1

Example time/performance diagram

P

1

... P

4

Individual performances of axes 1 ... 4

P

total

Addition of the individual performances

P

total

Average of the individual performances

Use the time/performance diagram to optimise the DC−bus performance of all axes for a
complete machine cycle.