beautypg.com

Technical data, Rated data supply modules, Output data – Lenze i700 Manual User Manual

Page 33

background image

Technical data

Rated data

Supply modules

4

l

33

EDS700ACBA EN 4.0

Output data

Voltage

Frequency

Continuous output

current [A]

Number

of

phases

Continuous output

power [kW]

up to +40 °C



[V]

[Hz]

up to +40

°C



up to +55

°C



Without

With

Mains choke/filter

E70ACPSx0304x

565

DC

30.0

18.8

2

10.3

15.4

E70ACPSx0304x

675

DC

30.0

18.8

2

12.3

18.5

E70ACPSx0604x

565

DC

60.0

37.5

2

20.6

30.9

E70ACPSx0604x

675

DC

60.0

37.5

2

24.6

37.0

 Temperature in the control cabinet

Chapter 4.3 contains data for overcurrent operation.

The i700 device series is designed for dynamic applications with several drives (DC−bus
operation, (

108)).

Usually an acceleration process is followed by a deceleration process, and the motor
speeds rarely reach the rated motor speed. Even if a drive is operated at rated power (rated
current, rated speed), there are other drives in the network requiring less power.
Therefore, in this case, a power supply module can be dimensioned much smaller than
would be required by the total power of the axis controllers.

Power losses

Power loss P

V

[W]

U

Lr

= 400 V

U

Lr

= 480 V

when controller is inhibited

E70ACPSx0304x

60

60

E70ACPSx0304x
+ EZAELN3025B122

80

80

E70ACPSx0604x

110

110

E70ACPSx0604x
+ EZAELN3050B591

160

160

E70ACPSx0304x

60

60

10

E70ACPSx0604x

110

110

10