beautypg.com

Supply modules, Axis modules, Technical data – Lenze i700 Manual User Manual

Page 42: Overcurrent operation supply modules, 1 supply modules, 2 axis modules

background image

Technical data

Overcurrent operation
Supply modules

4

l

42

EDS700ACBA EN 4.0

4.3.1

Supply modules

Power supply
modules

Short−time currents [A] acc. to cycle times

3 / 12 s

60 / 120 s

I

rdc

200%

I

max_3

75%

I

red_12

150%

I

max_60

75%

I

red_120

E70ACPSx0304x

30.0

60.0

19.8

45.0

22.5

E70ACPSx0604x

60.0

120

39.6

90.0

45.0

4.3.2

Axis modules

Axis modules

Short−time currents [A] at switching frequency of 4 kHz acc. to cycle times

3 / 12 s

60 / 120 s

I

r4

200%

I

max4_3

75%

I

red4_12

150%

I

max4_60

75%

I

red4_120

E70ACMSx0054xx1xxx

2.5

5.0

1.7

3.8

1.9

E70ACMSx0104xx1xxx

5.0

10.0

3.3

7.5

3.8

E70ACMSx0204xx1xxx

10.0

20.0

6.7

15.0

7.5

E70ACMSx0324xx1xxx

16.0

32.0

10.7

24.0

12.0

E70ACMSx0484xx1xxx

24.0

48.0

16.0

36.0

18.0

E70ACMSx0644xx1xxx

32.0

64.0

21.3

48.0

24.0

E70ACMSx0054xx2xxx

2 * 2.5

2 * 5.0

2 * 1.7

2 * 3.8

2 * 1.9

E70ACMSx0104xx2xxx

2 * 5.0

2 * 10.0

2 * 3.3

2 * 7.5

2 * 3.8

E70ACMSx0204xx2xxx

2 * 10.0

2 * 20.0

2 * 6.7

2 * 15.0

2 * 7.5

E70ACMSx0324xx2xxx

2 * 16.0

2 * 32.0

2 * 10.7

2 * 24.0