NOTE:

To enable dual path of the command device under Solaris systems, make sure to include

all paths to the command device on a single line in the HORCM_CMD section of the config file.
Putting the path information on separate lines may cause parsing issues, and failover may not
occur unless the HORCM startup script is restarted on the Solaris system.

When a server is connected to two or more storage systems, the HORCM identifies each storage
system using the unit ID (see

Figure 13 (page 29)

). The unit ID is assigned sequentially in the order

described in this section of the configuration definition file. When the storage system is shared by
two or more servers, each server must be able to verify that the unit ID is the same Serial# (Seq#)
among servers. This can be verified using the raidqry command.

Figure 13 Configuration and unit IDs for multiple storage systems

dev_name for Windows

In Windows SAN environment, "Volume{guid}" will be changed on every re-boot under
MSCS/Windows2k3, if Windows finds the same signature on the command device connected
with Multi-Path.Therefore, find NEW "Volume{guid}", and change "Volume{guid}" described in
the RAID Manager configuration file. Thus, RAID Manager supports the following naming format
specifying Serial#/LDEV#/Port# as notation of the command device for only Windows. For XP7
Storage, set the number to which 300,000 is added to the serial number.

\\.\CMD-Ser#-ldev#-Port#

HORCM_CMD
#dev_name dev_name dev_name
\\.\CMD-30095-250-CL1-A

RAID Manager instance components on the host server