beautypg.com

HP XP7 Storage User Manual

Page 280

background image

Table 91 SSB codes that are returned by raidcom delete rcu command (continued)

raidcom delete rcu

Description

Error code

Executing/
Async

Error message

SSB2

SSB1

The serial number, the product ID, or the SSID of the target
storage system is incorrect.

3000

2E20

Async

Get Command Status

The specified RCU cannot be deleted because the RCU is not
registered.

3001

2E20

Async

Get Command Status

The specified CU number is not defined, or an LDEV is not
defined under the CU number.

7101

2E21

Async

Get Command Status

Path cannot be deleted because there is a pair of Continuous
Access Synchronous/Continuous Access Journal, or a journal
volume is in the relevant CU.

3101

2E22

Async

Get Command Status

Command cannot be executed because the RCU identification
code of a path is invalid.

3001

2E31

Async

Get Command Status

The command cannot be accepted because the DKC is busy.
After a while, execute the same command.

00EE

2ED6

Executing

CMDRJE

An internal error occurred.

3005

2ED6

Async

Get Command Status

Call HP Technical Support.

The value of SSID on the remote storage system is invalid.

3300

2ED6

Executing

CMDRJE

RCU storage system does not exist.

00D1

2EDE

Executing

CMDRJE

The specified parameter is invalid. Check the HP XP7 RAID
Manager Reference Guide.

3002

2EF3

Executing

CMDRJE

Table 92 SSB codes that are returned by raidcom add rcu command

raidcom add rcu

Description

Error code

Executing/
Async

Error message

SSB2

SSB1

The value of CU# on the RCU exceeds the effective range.

3001

2E00

Executing

CMDRJE

Invalid product ID or path registration ID.

3005

2E00

Executing

CMDRJE

Command cannot be executed because the parameter of
specified RCU is invalid.

3008

2E00

Async

Get Command Status

Command cannot be executed because all the CU numbers in
the RCU is not unified at the path that is specified creation or
deletion.

3009

2E00

Async

Get Command Status

The value of port# on the side of RCU is invalid.

3200

2E00

Executing

CMDRJE

The CU number is out of effective range.

7100

2E00

Executing

CMDRJE

/Async

Get Command Status

The value of specified port is invalid.

8400

2E00

Executing

CMDRJE

/Async

Get Command Status

Failed to establish a path or the deletion operation. The following
factor can be thought.

3101

2E10

Async

Get Command Status

Input parameter is invalid.

Port status or the MP Blade status is in the state of abnormal.

280 Troubleshooting

This manual is related to the following products: