HP XP7 Storage User Manual
Page 276

Table 87 SSB codes that are returned by raidcom add thp_pool command (continued)
raidcom add thp_pool
Description
Error code
Executing/
Async
Error message
SSB2
SSB1
The RAID level of the specified LDEV is different with the RAID
level of others.
0015
2E31
Async
Get Command Status
There is a blocked pool volume.
0016
2E31
Async
Get Command Status
External volumes whose cache modes are different are included.
0018
2E31
Async
Get Command Status
The POOL Name is duplicated with another pool.
6001
2E31
Executing
CMDRJE
The pool cannot include volumes in different RAID levels because
the pool cannot include those volumes. Or the pool cannot
6004
2E31
Async
Get Command Status
include the RAID 1 volumes and the volumes of other RAID levels
together.
The pool cannot include both internal volumes and external
volumes because the pool is not set to Mixable.
6005
2E31
Async
Get Command Status
The usage capacity exceeds the license capacity of program
product.
9000
2E31
Async
Get Command Status
The command cannot be accepted. After a while, execute the
same command.
00EE
2EE7
Executing
CMDRJE
An internal error occurred.
FEEC
2EE7
Executing
CMDRJE
Call HP Technical Support.
Async
Get Command Status
Table 88 SSB codes that are returned by raidcom modify rcu command
raidcom modify rcu
Description
Error code
Executing/
Async
Error message
SSB2
SSB1
CU# of RCU exceed the effective value.
3001
2E00
Executing
CMDRJE
The value of least path number is invalid.
3002
2E00
Executing
CMDRJE
The value of RIO MIH time is invalid.
3003
2E00
Executing
CMDRJE
The value of Round-trip response time is invalid.
3004
2E00
Executing
CMDRJE
Invalid product ID or path registration ID.
3005
2E00
Executing
CMDRJE
Incident that is created by CU is not in the one of followings.
3007
2E00
Executing
CMDRJE
- Incident that is sent to MCU host and RCU.
- Incident that is sent to RCU.
Command cannot be executed because the parameter of
specified RCU is invalid.
3008
2E00
Async
Get Command Status
Command cannot be executed because all the CU numbers in
the RCU is not unified at the path that is specified creation or
deletion.
3009
2E00
Async
Get Command Status
The CU number is out of effective range.
7100
2E00
Executing
CMDRJE
The operation cannot be done because the microcode is being
changed.
8004
2E11
Executing
CMDRJE
The serial number, the product ID, or the SSID of the target
storage system is incorrect.
3000
2E20
Executing
CMDRJE
276 Troubleshooting