Table 46 Command error messages (continued)
Value
Recommended action
Condition
Error
message
Error code
230
Please confirm the command name.
An unknown command was
attempted.
Unknown command
EX_UNWCMD
229
Please confirm the pair status using
the pairdisplay command.
The pair status of a volume
within a group is not
identical to the status of the
other volumes in the group.
Inconsistent status in
group
EX_INCSTG
228
Please confirm the pair status using
the pairdisplay command.
The pair status of the target
volume is not appropriate.
Invalid pair status
EX_INVSTP
222
Please confirm the volume status
using the pairdisplay -l or the
raidvchkdsp -v aou command.
The volume status of the
target volume is not
appropriate.
Invalid volume status
EX_INVVOL
220
Please confirm the MU# (MU #1/2
cannot be used for Continuous
The MU# of the volume to
be operated is not
appropriate.
Invalid mu# with
HORC/UR or
HOMRCF
EX_INVMUN
Access Synchronous and must be
P-VOL for Business Copy.) for the
specified group using the
pairdisplay
command. And also
confirm the command execution
environment to be set as HOMRCF.
227
Please confirm that the Port, Target
ID, LUN are defined correctly under
A device defined in the
configuration file does not
No such LDEV within
the RAID
EX_ENLDEV
HORCM_DEV in the configuration
file.
have a mapping to a real
LUN and target ID within the
RAID storage system.
226
Contact the HP Technical Support.
Wrong return code.
Invalid return code
EX_INVRCD
225
Check the volume list to see if an
operation was directed to the wrong
S-VOL.
Currency check error for
S-VOL. Cannot guarantee
identical data on S-VOL.
S-VOL currency error
EX_VOLCUR
224
Please confirm the pair status of the
local volume using the pairdisplay
command.
The volume specified with
the SVOL-takeover command
is not the same as the P-VOL.
Local volume
currency error
EX_VOLCUE
223
Please confirm the pair status of
remote and local volumes using the
pairdisplay
command.
The combination of the
volumes specified with
Swap-takeover is unsuitable.
Local and remote
volume currency
error
EX_VOLCRE
--
Contact the HP Technical Support.
Wrong error code.
Unknown error
code.
EX_UNWERR
217
Please create a pair with cutting the
number of the group on the
When creating Continuous
Access Synchronous
Not enough CT
groups in RAID
EX_ENOCTG
configuration files or make already
Async/UR or Business Copy
existing group and the target group
volume, CTGID could not be
the same CTGID. Please confirm
registered due to being
already existing group CTGID using
beyond the max number of
the pairvolchk command. Then,
CT groups (0-255 for
P9500, XP24000/XP20000 please create a pair specifying
Disk Array, 0-255 for
CTGID as the paircreate -f
option.
XP12000 Disk
Array/XP10000 Disk Array,
0-127 for XP1024/XP128
Disk Array, 0-15 for XP256
Disk Array) for an async
volume.
222 Troubleshooting