HP XP7 Storage User Manual
Page 220

Table 46 Command error messages (continued)
Value
Recommended action
Condition
Error
message
Error code
244
Refer to the error message, and
designate an appropriate value or
Your entry is one of the
following statuses.
Result too large
EX_ERANGE
confirm whether you specified the
unit correctly.
•
The value was entered
beyond the maximum.
•
The result value is
beyond the maximum.
•
The unit you set is invalid.
243
Contact the HP Technical Support.
Undefined error.
File name too long
EX_ENAMLG
242
Please confirm that the HORC
Manager in the remote host is
A timeout occurred on
remote communication, and
No remote host alive
for remote
EX_ENORMT
running, and then increase the value
HORC Manager failed to
re-execute.
commands or
remote HORCM
of the timeout in the configuration
file.
might be blocked
(sleeping) on an
existing I/O
241
Contact the HP Technical Support.
Detected a contradiction for
a command.
Invalid RAID
command mode
EX_INVMOD
240
Contact the HP Technical Support.
Detected a contradiction for
a command.
Invalid RAID
command
EX_INVCMD
239
Verify the device or group name and
add it to the configuration file of the
remote and local hosts.
The designated device or
group name does not exist
in the configuration file, or
No such group
EX_ENOGRP
the network address for
remote communication does
not exist.
238
Retry your operation after restart of
the instance for RAID Manager.
Detected a contradiction for
a command.
Unknown function
code
EX_UNWCOD
Contact the HP Technical Support if
the operation fails because of same
error again.
237
Refer to the host syslog file, and
investigate the cause of the error.
A read/write to the
command device failed with
an I/O error.
Control command
I/O error
EX_CMDIOE
If the problem persists, collect the
log information of HORCM
($HORCM_LOG), and contact the
HP Technical Support.
221
Verify Continuous Access
Synchronous/Business Copy
functions are installed.
The request to the command
device failed or was
rejected.
An order to the
control/command
device was rejected
EX_CMDRJE
Verify ports are set.
Note: This error code is
sometimes caused by the
Verify CU paths have been
established.
operating system and
reported as EX_CMDIOE
Verify that the target volume is
available.
instead of EX_CMDRJE (see
next row).
RAID Manager displays "SSB" in the
output of the commands so a service
representative can identify the cause
of EX_CMDRJE (except for Tru64,
DYNIX).
Example:
220 Troubleshooting