HP XP7 Storage User Manual
Page 243
Table 62 SSB codes that are returned by raidcom add journal command (continued)
raidcom add journal
Description
Error code
Executing/
Async
Error message
SSB2
SSB1
The specified volume is not installed or cannot be used.
0011
2E10
Executing
CMDRJE
Async
Get Command Status
The specified volume is connected from the mainframe host.
001A
2E10
Async
Get Command Status
There is a PIN slot in the journal volume.
001B
2E10
Executing
CMDRJE
Async
Get Command Status
The specified volume cannot be registered as a journal volume
because it is in shredding. Wait until the shredding operation
is completed, then retry the operation.
001C
2E10
Executing
Async
CMDRJE
Get Command Status
The specified volume is used in maintenance operation.
0053
2E10
Async
Get Command Status
The specified volume cannot be used as the journal volume
because the virtual LDEV ID is deleted.
0056
2E10
Async
Get Command Status
The specified volume cannot be used as the journal volume
because it is the virtual volume.
0057
2E10
Async
Get Command Status
The specified operation failed because the journal or mirror is
not in the operable status.
5000
2E10
Async
Get Command Status
The operation cannot be done because it is in the state of
start-up.
800B
2E11
Async
Get Command Status
The operation cannot be done because the internal processing
is in progress. Wait for a while, then retry the operation.
800E
2E11
Async
Get Command Status
Abnormal cache status.
810A
2E11
Executing
CMDRJE
Async
Get Command Status
The command cannot be accepted. After a while, execute the
same command.
9400
2E11
Executing
CMDRJE
The specified LDEV is not defined.
0000
2E20
Executing
CMDRJE
The specified MP Blade is not installed.
8300
2E20
Executing
CMDRJE
The operation failed because the specified journal is not
installed.
5000
2E21
Async
Get Command Status
The journal volume cannot be added, or the journal cannot be
added to the extended CT group due to insufficient capacity of
the shared memory (SM).
8104
2E21
Async
Get Command Status
The SM for Continuous Access Journal is not installed.
8105
2E21
Executing
CMDRJE
A journal volume cannot be registered, or a journal cannot be
added to the extended CT group because the program product
9000
2E21
Async
Get Command Status
of Continuous Access Journal or Continuous Access Journal Z
is not installed.
A new journal volume cannot be registered, or the number of
selected volumes is too many.
0005
2E23
Async
Get Command Status
The number of specified LDEVs is invalid.
0008
2E23
Executing
CMDRJE
The operation failed because the multiple LDKC numbers cannot
be mixed in the journal.
003E
2E23
Async
Get Command Status
The operation failed because the number of journals in the
journal or the extended CT group exceeds the maximum.
5000
2E23
Async
Get Command Status
Error messages and error codes 243