HP XP7 Storage User Manual
Page 270

Table 82 SSB codes returned by raidcom modify snapshot (continued)
raidcom modify snapshot
Description
Error code
Executing/Async
Error message
SSB2
SSB1
The Fast Snap or Snapshot pair cannot be restored due to
one of the following reasons:
9704
2E10
Executing
CMDRJE
•
Snapshot data of a restore target Fast Snap or Snapshot
pair is being obtained per consistency group.
•
Snapshot data of a different pair whose primary volume
is the restore target P-VOL of a Fast Snap or Snapshot
pair is being obtained per consistency group.
An error occurred at the operation of Fast Snap due to one
of the following reasons:
9800
2E10
Executing
CMDRJE
•
The LDEV number specified for the P-VOL or the S-VOL
is incorrect.
•
The LDEV specified as the P-VOL or the S-VOL is not
paired.
•
The pair of the specified P-VOL or the S-VOL is not ready
to perform the specified operation.
•
The specified Snapshot ID (MU number) is wrong.
•
The specified Snapshot ID (MU number) is already used.
•
The specified pool is not in the usable status.
•
The license capacity has exceeded the maximum.
•
The control table for Fast Snap is depleted.
The operation cannot be performed because power-off is in
progress.
8003
2E11
Executing
CMDRJE
The specified LDEV is not defined.
0000
2E20
Executing
CMDRJE
The command ends abnormally because an unmounted
volume is specified as the P-VOL of a Fast Snap or Snapshot
pair.
0008
2E20
Executing
CMDRJE
The command ends abnormally because the blocked volume
is specified as the P-VOL of a Fast Snap or Snapshot pair.
0009
2E20
Executing
CMDRJE
The command ends abnormally because the volume in
formatting operation is specified as the P-VOL of a Fast Snap
or Snapshot pair.
000A
2E20
Executing
CMDRJE
The command ends abnormally because the shared memory
(FC, TPF, or Extension3) is not expanded for necessary
capacity.
8107
2E21
Executing
CMDRJE
The command ends abnormally because the shared memory
(SS3 or more) is not expanded for necessary capacity.
8108
2E21
Executing
CMDRJE
The program product is not installed.
9010
2E21
Executing
CMDRJE
The Fast Snap or Snapshot pair cannot be restored because
the volume that is set the S-VOL Disable is specified as the
P-VOL.
0079
2E30
Executing
CMDRJE
The command ends abnormally because the volume other
than OPEN-V is specified as the P-VOL of a Fast Snap or
Snapshot pair.
007A
2E30
Executing
CMDRJE
The command ends abnormally because the external volume
mapped for the online data migration is specified as the
S-VOL of a Fast Snap or Snapshot pair.
0081
2E30
Executing
CMDRJE
270 Troubleshooting