HP XP7 Storage User Manual
Page 221

Table 46 Command error messages (continued)
Value
Recommended action
Condition
Error
message
Error code
# paircreate -g G1 -f
never -vl -nocopy
paircreate: [EX_CMDRJE] An
order to the
control/command device was
rejected
Refer to the command log
(/HORCM/log10/horcc_u1-1.log)
for details.
It was rejected due to
SKEY=0x05, ASC=0x26,
SSB=0xB9BF,0xB9C7 on
Serial#(63502).
237
Refer to the host syslog file, and
investigate the cause of the error. If
A read/write to the
command device failed with
Control command
I/O error or rejected
EX_CMDIOE
the cause is "Illegal Request (0x05)"
an I/O error or was
rejected.
Sense Key, please confirm the
following items.
Verify Continuous Access
Synchronous/Business Copy
functions are installed. Verify ports
are set. Verify CU paths have been
established. Verify that the target
volume is available.
If the problem persists, contact the
HP Technical Support.
236
Confirm status using the
pairdisplay
command. Make
The volume attribute or the
fence level within a group is
not identical.
Unmatched volume
status within the
group
EX_ENQVOL
sure all volumes in the group have
the same fence level and volume
attributes.
235
Confirm volume status using the
pairdisplay
command, and
Combination of a volume is
unsuitable between the
remote and local host.
Pair Volume
combination error
EX_EVOLCE
change the combination of volumes
properly.
234
Please issue the pairresync
command manually to the identified
Detected a suspended status
(PSUE) for the paired
volume, before it made it to
the designated status.
Pair suspended at
WAIT state
EX_EWSUSE
failed paired volume to try to recover
it.
If the problem persists, contact the
HP Technical Support.
233
Please increase the value of the
timeout using the -t option. For
Detected a time out, before
it made it to the designated
status.
Timeout waiting for
specified status
EX_EWSTOT
details, refer to the troubleshooting
information in the relevant user
document.
232
Please confirm that HORC Manager
on the remote host is running.
Timeout error because the
remote did not notify about
expected status in time.
Timeout waiting for
specified status on
the local host
EX_EWSLTO
231
Please confirm the value of "poll" in
the configuration file.
HORC Manager monitoring
was refused.
HORCM Monitor
stopped
EX_ESTMON
Error messages and error codes 221