beautypg.com

HP XP7 Storage User Manual

Page 160

background image

If PVOL has non-reflected data in PAIR state:

Behavior of first pairsplit at T0

Behavior of OLD pairsplit at T0

PVOL_PAIR from/to SVOL_PAIR(WD)

T0 PVOL_PAIR from/to SVOL_PAIR(WD)

PVOL_PSUS from/to SVOL_COPY(WE)

T1: PVOL_COPY from/to SVOL_COPY(WD)

PVOL_PSUS from/to SVOL_SSUS(WE)

T2: PVOL_PSUS from/to SVOL_SSUS(WE)

If PVOL has been reflected all data to SVOL in PAIR state:

Behavior of First pairsplit at T0

Behavior of OLD pairsplit at T0

PVOL_PAIR from/to SVOL_PAIR(WD)

T0: PVOL_PAIR from/to SVOL_PAIR(WD)

PVOL_PSUS from/to SVOL_SSUS(WE)

T1: PVOL_PSUS from/to SVOL_SSUS(WE)

The state changes for paircreate -split are:

Behavior of First paircreate -split at T0

Behavior of OLD paircreate -split at T0

SMPL from/to SMPL

T0: SMPL from/to SMPL

PVOL_PSUS from/to SVOL_COPY(WE)

T1: PVOL_COPY from/to SVOL_COPY(WD)

PVOL_PSUS from/to SVOL_SSUS(WE)

T2: PVOL_PSUS from/to SVOL_SSUS(WE)

If you attempt the pairevtwait -s psus in PVOL_PSUS & SVOL_COPY state, then pairevtwait
will return immediately even if the S-VOL is still in SVOL_COPY state because PVOL is already
in PVOL_PSUS state. If you want to wait the "SVOL_SSUS" state, and then you must check the
status of the S-VOL becomes "SVOL_PSUS" via the return code using pairvolchk -ss command
on SVOL side or pairvolchk -ss -c command on PVOL side. Or you can use pairevtwait -ss
ssus on both PVOL and SVOL, pairevtwait -ss ssus -l on SVOL locally.

If you attempt the pairresync -restore or pairsplit -S in PVOL_PSUS & SVOL_COPY state, then
Business Copy will reject this command due to unable to perform. In this case, you need to
wait until the S-VOL state becomes SVOL_SSUS.

Table 34 Pair status versus Snapshot commands

Snapshot Command

Pair Status

pairresync

pairsplit

paircreate

Resync

-S option

-C option

-E option

-split

No -split

Rejected

Acceptable

Rejected

Rejected

Rejected

Accepted 2

SMPL

1

Acceptable

Rejected

Rejected

Rejected

Rejected

Acceptable

COPY
RCPY

2

Acceptable

Accepted 1

Accepted 4

Rejected

Accepted*4

Acceptable

PAIR

3

Accepted* 2

Accepted 1

Acceptable

Rejected

Acceptable

Rejected

PSUS
(PFUS)

4

Accepted* 2

Accepted 1

Rejected

Acceptable

Rejected

Rejected

PSUE

5

Accepted*: A command is accepted and issued; whether this command is executed or not depends
on the microcode version of the RAID storage system.

160 Data replication operations with RAID Manager

This manual is related to the following products: