HP XP7 Storage User Manual
Page 259
Table 79 SSB codes that are returned by raidcom delete pool command (continued)
raidcom delete pool
Description
Error code
Executing/
Async
Error message
SSB2
SSB1
Pool ID is not installed.
6000
2E20
Executing/Async
CMDRJE
Get Command Status
The operation cannot be performed because the shared memory
(SM) is not initialized.
8106
2E21
Async
Get Command Status
The number of specified LDEVs is invalid.
0008
2E23
Executing
CMDRJE
The specified LDEV cannot be deleted because it is a top VOL
of the pool.
0052
2E30
Executing
CMDRJE
The specified pool is a pool for Fast Snap or Snapshot.
6003
2E30
Executing
CMDRJE
The command cannot be accepted. After a while, execute the
same command.
00EE
2EE7
Executing
CMDRJE
Pool ID is not installed.
00F9
2EE7
Executing
CMDRJE
An internal error occurred.
FEEC
2EE7
Executing
CMDRJE
Call HP Technical Support.
The specified parameter is invalid. Check the HP XP7 RAID
Manager Reference Guide.
6002
2EF3
Executing
CMDRJE
Table 80 SSB codes that are returned by raidcom add snap_pool command
raidcom add snap_pool
Description
Error code
Executing/
Async
Error message
SSB2
SSB1
The value of LDEV number is out of range.
0000
2E00
Async
Get Command Status
Pool ID is out of range.
6000
2E00
Executing
CMDRJE
The type of pool is invalid.
6001
2E00
Executing
CMDRJE
The maximum reserve ratio for V-VOL is out of range.
6002
2E00
Executing
CMDRJE
The operation cannot be done because a SATA-E drive in the
state of quick formatting is in the specified LDEV.
000C
2E10
Async
Get Command Status
The specified LDEV is in the state of blocked.
0009
2E10
Async
Get Command Status
The specified LDEV is in the state of blocked, or not installed.
0011
2E10
Executing
CMDRJE
Fast Snap cannot be used because there are not enough cache
management devices to create pairs.
0050
2E10
Async
Get Command Status
The pool cannot be created because there are not enough
resources (VDEV) depending on cache management devices.
0102
2E10
Async
Get Command Status
The operation cannot be performed because the pool volume
is being deleted.
600D
2E10
Async
Get Command Status
The pool is not in the status where the pool volume can be
added.
6003
2E11
Executing
/Async
CMDRJE
Get Command Status
The operation cannot be done because the power supply is
switched off.
8003
2E11
Async
Get Command Status
Error messages and error codes 259