State transitions of performance control – HP XP7 Storage User Manual
Page 137
For details about the RAID Manager commands for Performance Control operations, see the HP
XP7 RAID Manager Reference Guide.
You can give a nickname (PFC name) to each host WWN to assist in managing the hosts. You
can also manage WWN and the PFC name per group. The groups to which WWN and the PFC
name are registered are managed uniquely. The following table lists the details for the Performance
Control operations and the management unit.
Management per system
Management per port
PFC Operation
threshold
prioritized or non-prioritized
raidcom modify pfc_wwn
upper limit
WWN or PFC name
threshold
prioritized or non-prioritized
raidcom modify pfc_group
upper limit
PFC group name
PFC name
-
raidcom add pfc_wwn
PFC group name
-
raidcom add pfc_group
PFC name (PFC information per
port is also deleted.)
-
raidcom delete pfc_wwn
PFC group name (PFC information
per port is also deleted.)
-
raidcom delete pfc_group
threshold
prioritized or non-prioritized
raidcom get pfc_wwn
upper limit
WWN or PFC name
PFC group name
threshold
prioritized or non-prioritized
raidcom get pfc_group
upper limit
PFC group name
control mode of PFC
performance of server (IOps/KBps)
raidcom monitor pfc_wwn
control mode of PFC
performance of server (IOps/KBps)
raidcom monitor pfc_group
State transitions of Performance Control
The following shows the state by the PFC operation and its state transition.
Performance Control operations
137