Table 76 SSB codes that are returned by raidcom add lun command (continued)
raidcom add lun
Description
Error code
Executing/
Async
Error message
SSB2
SSB1
The other than HMDE volume or OPEN volume is included in
the specified LDEV.
0155
B958
Executing
CMDRJE
An LU path has already defined in the relevant LDEV.
015A
B958
Executing
CMDRJE
An invalid LDEV exists in the specified LDEVs.
015D
B958
Executing
CMDRJE
It exceeds the maximum LUN under the port.
015E
B958
Executing
CMDRJE
LDEV is set as a pool volume.
0178
B958
Executing
CMDRJE
LUN path cannot be set because the LDEV is a system disk.
017B
B958
Executing
CMDRJE
LUN path cannot be set because the LDEV is a journal volume.
017C
B958
Executing
CMDRJE
LUN path cannot be set because the access attribute of LDEV
Data Retention is reserved.
017D
B958
Executing
CMDRJE
When the host mode is External Storage(0x4C), the LUN path
cannot be set in the other than the external volume.
01A3
B958
Executing
CMDRJE
The host group and the LDEV that configure the LU path do not
exist in the same virtual storage machine.
01F2
B958
Executing
CMDRJE
The LU path definition cannot be set because the virtual LDEV
information of the specified LDEV is not defined yet.
01F3
B958
Executing
CMDRJE
Command device cannot be set because it is reserved for Auto
LUN.
0601
B958
Executing
CMDRJE
Command device cannot be set because it is an Business Copy
pair/or it is reserved.
0606
B958
Executing
CMDRJE
The command device cannot be operated because it is used at
the local RAID Manager.
0639
B958
Executing
CMDRJE
A command device cannot be set because LDEV is other than
the OPEN volume.
064A
B958
Executing
CMDRJE
The specified LDEV is not installed.
065D
B958
Executing
CMDRJE
A command device cannot be set because LDEV is the virtual
volume of Fast Snap or Snapshot.
0679
B958
Executing
CMDRJE
The command cannot be operated because the virtual LDEV is
not defined yet.
0927
B958
Executing
CMDRJE
The value of LUN exceeds the maximum.
0944
B958
Executing
CMDRJE
The value of LDEV exceeds the maximum.
0945
B958
Executing
CMDRJE
Another LDEV is already mapped to the specified LUN.
0947
B958
Executing
CMDRJE
The value of Host group ID exceeds the maximum.
0956
B958
Executing
CMDRJE
The program product is not installed.
0957
B958
Executing
CMDRJE
The specified host group is not installed.
0959
B958
Executing
CMDRJE
An invalid LDEV exists in the specified LDEVs.
095D
B958
Executing
CMDRJE
The multiple LDEV cannot be specified.
098C
B958
Executing
CMDRJE
When the host mode option 60 is set, LUN path of LUN0 cannot
be set or released.
098D
B958
Executing
CMDRJE
Error messages and error codes 255