HP XP7 Storage User Manual
Page 158
Table 31 Continuous Access Journal pair status (continued)
Secondary
Primary
Continuous Access Journal Pair Status
Status
R/W enabled
R enabled
After Takeover, SSWS is the status of the S-VOL. With this status,
data can be written to the S-VOL.
SSWS
•
SSWS is displayed by RAID Manager, from which the
horctakeover command is issued.
•
Remote Web Console displays this status as PSUS or PSUE.
R enabled
R/W enabled
If data in the journal volume exceeds 80-percent, pair status changes
to PFUL. The write data that inflows then is monitored during the Data
Overflow Watch.
PFUL
PFUL status is displayed by RAID Manager. Remote Web Console
displays this status as PAIR.
Table 32 Pair status versus Continuous Access Synchronous and Continuous Access Journal commands
Continuous Access Synchronous command
-
pairresync
pairsplit
paircreate
Resync
-S option
-P option
-r or -rw option
Nocopy
Copy
Status
#
Rejected
Acceptable
Rejected
Rejected
Accepted 3
Accepted 2
SMPL
1
Acceptable
Accepted 1
Rejected.
Accepted 4
Acceptable
Acceptable
COPY
2
Acceptable
Accepted 1
Accepted 4
Accepted 4
Acceptable
Acceptable
PAIR
3
Accepted 2*
Accepted 1
Acceptable
Acceptable
Rejected
Rejected
PSUS
4
Accepted 2*
Accepted 1
Acceptable
Acceptable
Rejected
Rejected
PSUE
5
Accepted 2*
Accepted 1
Rejected
Rejected
Rejected
Rejected
PDUB
6
Legend:
Accepted = Accepted and executed. When the operation terminates normally, the status changes to the indicated number.
Acceptable = Accepted but no operation is executed.
Rejected = Rejected and operation terminates abnormally.
Pairsplit of a Continuous Access Asynchronous volume is returned after verification of state transition
that waits until delta data is synchronized from P-VOL to S-VOL.
NOTE:
In the case of the SSWS status after SVOL-SSUS-takeover execution, the pairresync
command (from P-VOL to S-VOL) is rejected because the delta data for S-VOL becomes dominant,
and its status is expected to be using the -swaps(p) option of pairresync. If the pairresync command
(from P-VOL to S-VOL) is rejected, confirm this special status using the -fc option of the pairdisplay
command.
Following table shows the relation of command acceptances for paired status and Business Copy.
Table 33 Pair status versus Business Copy commands
Business Copy command
-
pairresync
pairsplit
paircreate
Resync
-S option
-C option
-E option
-split
No -split
Pair Status
Rejected
Acceptable
Rejected
Rejected
Accepted 2 to 4
Accepted 2
SMPL
1
Acceptable
Accepted 1
Accepted [1] 2
to 4
Accepted 5
Accepted [1] 2
to 4
Acceptable
COPY
RCPY
2
158