beautypg.com

HP XP7 Storage User Manual

Page 254

background image

Table 75 SSB codes that are returned by raidcom delete lun command

raidcom delete lun

Description

Error code

Executing/
Async

Error message

SSB2

SSB1

The other than multiplatform volume or OPEN volume is included
in the specified LDEV.

0155

B958

Executing

CMDRJE

An used LDEV exists in the specified LDEV.

015D

B958

Executing

CMDRJE

It cannot be deleted because it is the last path of Continuous
Access Synchronous.

0202

B958

Executing

CMDRJE

It cannot be deleted because it is the last path of Business Copy.

0203

B958

Executing

CMDRJE

It cannot be deleted because it is the last path of Fast Snap or
Snapshot.

020A

B958

Executing

CMDRJE

It cannot be deleted because it is the last path of Continuous
Access Journal.

020B

B958

Executing

CMDRJE

It cannot be deleted because the operation object LU is executing
host I/O.

0233

B958

Executing

CMDRJE

It cannot be deleted because the operation object LU is reserved.

0234

B958

Executing

CMDRJE

The command device is being used in the local RAID Manager.

0239

B958

Executing

CMDRJE

A command device is being set.

0240

B958

Executing

CMDRJE

The command cannot be operated because the virtual LDEV is
not defined yet.

0927

B958

Executing

CMDRJE

The value of LUN exceeds the maximum.

0944

B958

Executing

CMDRJE

The value of LDEV exceeds the maximum.

0945

B958

Executing

CMDRJE

The value of host group ID exceeds the maximum.

0956

B958

Executing

CMDRJE

The program product is not installed.

0957

B958

Executing

CMDRJE

Host group is not installed.

0959

B958

Executing

CMDRJE

An invalid LDEV exists in the specified LDEVs.

095D

B958

Executing

CMDRJE

The multiple LDEV cannot be specified.

098C

B958

Executing

CMDRJE

When the host mode option 60 is set, LUN path of LUN0 cannot
be set or released.

098D

B958

Executing

CMDRJE

The LU path cannot be deleted because the virtual LDEV ID of
the specified volume was deleted.

0996

B958

Executing

CMDRJE

Another LDEV is already mapped in the specified LUN.

09A1

B958

Executing

CMDRJE

The command device is being used in the local RAID Manager.

B9F9

B9F9

Executing

CMDRJE

Table 76 SSB codes that are returned by raidcom add lun command

raidcom add lun

Description

Error code

Executing/
Async

Error message

SSB2

SSB1

An invalid LDEV exists in the specified LDEVs.

0014

2EF6

Executing

CMDRJE

LUN path cannot be set because it is reserved for Auto LUN.

0101

B958

Executing

CMDRJE

The attribute of the specified port is Initiator or External.

0150

B958

Executing

CMDRJE

254 Troubleshooting

This manual is related to the following products: