HP XP7 Storage User Manual
Page 219

Table 46 Command error messages
Value
Recommended action
Condition
Error
Error code
message
255
Verify that HORCM is running by
using UNIX commands [ps - ef |
grep horcm].
This command failed to
communicate with the RAID
Manager software.
Can't be
communicate with
HORC Manager
EX_COMERR
254
Please designate the correct option
using the -h option.
An option or arguments of
an option are not sufficient.
Required Arg list
EX_REQARG
253
Please designate the correct option
using the -h option.
An option or arguments of
an option are incorrect.
Invalid argument
EX_INVARG
252
Please designate the correct option
using the -h option.
Designated an unknown
option.
Unknown option
EX_UNWOPT
251
Please verify that HORCM is running
and/or that HORCMINST is set
correctly.
Could not connect with
HORCM.
Can't be attached to
HORC Manager
EX_ATTHOR
250
Verify that HORCM is running by
using UNIX commands [ps - ef |
grep horcm].
Failed to communicate with
HORCM, or cannot make a
log directory file.
Can't be attached to
a Debug layer
EX_ATTDBG
249
Please designate the correct name
using the -h option.
The name specified in an
argument of an option is not
appropriate.
Invalid name of
option
EX_INVNAM
248
Contact the HP Technical Support.
Detected contradiction in
information that RAID
reported.
A specified option is
invalid
EX_OPTINV
247
Verify the device or group name and
add it to the configuration file of the
remote and local hosts.
The designated device or
group name does not exist
in the configuration file.
No such device or
group
EX_ENOENT
246
Verify the device name and add it
to the configuration file of the remote
and local hosts.
The designated device name
does not exist in the
configuration file.
No such device
EX_ENODEV
219
Verify the RAID unit ID and add it to
the configuration file of the remote
and local hosts.
The designated RAID unit ID
does not exist in the
configuration file.
No such RAID unit
EX_ENOUNT
218
Confirm the serial# (Seq#) of the
storage system using the
The group designated by
Business Copy paircreate
Unmatched Serial#
vs RAID unitID
EX_ENQSER
pairdisplay
command, or
does not have the same
RAID unit, or the unitID is not confirm that the serial# (Seq#) and
identical to the unit ID in the
same RAID serial# (Seq#).
the unit ID of storage system are the
same among hosts using the
raidqry -r
command.
245
Increase the virtual memory capacity
of the system, or close any
Insufficient memory exists.
Not enough core
EX_ENOMEM
unnecessary programs and/or
daemon processes.
131
Confirm the execution right,
permission the extension, the
execution path of the script file.
The script file specified by
the -zt option cannot be
performed.
Cannot execute
script file
EW_ENESCR
Error messages and error codes
219