beautypg.com

Emu pushbutton leds, 19 emu display groups, Table 19 – HP 3000 Enterprise Virtual Array User Manual

Page 95

background image

Storage System Hardware Components

95

Enterprise Virtual Array 3000 User Guide

Note:

Anytime you press and release the bottom pushbutton, the display will change to

En

,

Li

,

rG

,

Au,

or

Er.

See

3

,

Figure 43

.

A flashing alphanumeric display indicates that you can edit an address, state, or
view a condition report.

EMU Pushbutton LEDs

The pushbutton LEDs define error conditions and the state of the audible alarm.

When an error condition exists, the top pushbutton LED is On.

— For a single error condition, the LED is On until it is viewed

— For multiple errors, the LED is On until the most recent error condition is

viewed.

The bottom pushbutton LED is On only when the alarm is muted or disabled.

Table 19: EMU Display Groups

Display

Display Group

Description

En

Enclosure

Number

The enclosure number is the default display and is a

decimal number in the range

00

through

14

. See

Using the Enclosure Number Feature

,” on page 99

for detailed information.

Li

Bay 1 Loop ID

This display group has a single sublevel display that

defines the enclosure bay 1 loop ID. Valid loop IDs

are in the range

00

through

7F

.

rG

Reporting

Group

This display group has two,

2-digit displays that

define the reporting group number in the range

0000

through

4095.

Au

Audible Alarm

This display group provides control over the audible

alarm or horn. The sublevel displays are audible

alarm enabled (

on

) or audible alarm disabled (

oF

).

See

Error Condition Reporting

,” on page 101 for

detailed information.

Er

Error Condition

This display group reads

Er

when there is an error

condition. See

Error Condition Reporting

,” on

page 101 for detailed information.