4 ocp wwn pushbutton functions – HP 3000 Enterprise Virtual Array User Manual
Page 42
Storage System Startup
42
Enterprise Virtual Array 3000 User Guide
Entering the WWN
defines the pushbutton functions when entering the WWN or the WWN
checksum. This procedure requires use of the OCP. For more information, see
“
Complete the following procedure to assign the WWN to each pair of controllers.
The information needs to be input to one controller only. Either controller can be
used. In this sample procedure, the WWN 5000-1FE1-0000-0000 is entered.
Note:
Applying power to the rack when the controller power switches are on can
prevent proper controller initialization.
Table 4: OCP WWN Pushbutton Functions
Button
Function
S
Select a WWN or checksum character by scrolling up through the
character list one character at a time.
T
Select a WWN or checksum character by scrolling down through the
character list one character at a time.
X
Accept the current character and select the next character.
If you accept an incorrect character, you can move through all 16
characters, one character at a time, until you display the incorrect
character. You can then change the character.
W
Accept all the WWN or checksum characters.
1. Place the power switches on both controllers to the Off position.
2. Apply power to the rack.
3. On both controllers, place the power switch to
On.
HSV100 Startup
Note:
This display may not occur for up to two