Controls and displays, 40 emu location 41 emu controls and displays, Figure 40 – HP 3000 Enterprise Virtual Array User Manual
Page 89
Storage System Hardware Components
89
Enterprise Virtual Array 3000 User Guide
Controls and Displays
identifies the location and function of the EMU displays, controls, and
connectors.
1
EMU
Figure 40: EMU location
1
1
Status LEDs
These 3 LEDs are visual indications of the EMU and
enclosure status.
2
Alphanumeric display
A 2-character, 7-segment alphanumeric display of
the enclosure functions and status.
3
Function Select (“top”) pushbutton
The primary function of this pushbutton is to select a
display group function.
The LED is On when an error condition exists.
4
Display Group Select (“bottom”) pushbutton
The primary functions of this pushbutton are:
■
View display groups.
■
Control the audible alarm.
The LED is On when the audible alarm is muted or
disabled.
5
RS232 ONLY—A keyed, RJ45-type connector for use by HP authorized service representative.
6
LCD ONLY—An unused RJ45-type connector.
7
CAB ONLY—A keyed, RJ45-type enclosure address bus connector.
WARNING: To reduce the risk of electrical shock, fire, or damage to the
equipment, do not plug telephone or telecommunications connectors into
the “RS232 ONLY” receptacle.
Figure 41: EMU controls and displays
CXO6709A
3
1
2
4
5
6
7