beautypg.com

46 displaying error condition values, Conditions, Figure 46 – HP 3000 Enterprise Virtual Array User Manual

Page 106: Er en. ec, E.t. en. ec e.t

background image

Storage System Hardware Components

106

Enterprise Virtual Array 3000 User Guide

7. When all error conditions have been displayed, press and release the bottom

pushbutton to return to the Er display.

Figure 46: Displaying error condition values

Analyzing Condition Reports

Analyzing each error condition report involves three steps:

1. Identifying the element.

2. Determining the major problem.

3. Defining additional problem information.

See “

EMU Generated Condition Reports” on page 161

for details on performing

these tasks.

1

Press & hold top pushbutton to view first error in queue.

2

Press & release top pushbutton.

3

Press & hold top pushbutton to view next error.

4

Press and release the bottom pushbutton at any time to return to the

Er display.

e.t. =

element type

,

en. =

element number

,

ec =

error code

Er

en.

ec

e.t.

en.

ec

e.t.

CXO8233A

3

3

3

1

4

2

2

2

2

2