beautypg.com

Drive status displays – HP 3000 Enterprise Virtual Array User Manual

Page 84

background image

Storage System Hardware Components

84

Enterprise Virtual Array 3000 User Guide

Drive Status Displays

When displaying status, the LEDs are either On, Off, or Flashing. In some
configurations, the host controller can control the status LEDs. The operational
drive LED status displays are shown in

Table 13

. See

Table 14

for the

nonoperational drive status LED displays.

Note:

The drive is configured as part of an array. DO NOT replace an active drive.

Table 13: Operational Drive Status Displays

Drive Ready

Drive On-line

Drive Failure

Description

Flashing

(medium speed)

On

Off

Initial startup.

On

On

Off

The operational drive is not being

accessed.

Flashing

(high speed)

Flashing

(medium speed)

On

The drive is being located.

Flashing

On

Off

The drive is operational and active.

Table 14: Nonoperational Drive Status Displays

Drive Ready

Drive On-line

Drive Failure

Description

On

On

On

Indicates no connection or the controllers

are offline. Recommended corrective

actions:
1. Check power supplies for proper

operation.

2. If defective, replace drive.

On

Off

Flashing

Indicates drive error/not active.

Recommended corrective actions:
1. Verify drive loop continuity.