02 unrecoverable condition-emu interrupted, 03 unrecoverable condition-power supply shutdown, 04 information condition-emu internal data – HP 3000 Enterprise Virtual Array User Manual
Page 176
EMU Generated Condition Reports
176
Enterprise Virtual Array 3000 User Guide
5. If unable to correct the problem, contact your HP authorized service
representative.
07.01.02 UNRECOVERABLE Condition
—
EMU Interrupted
The Inter-IC (I2C) bus is not processing data and the EMU is unable to monitor or
report the status of the elements or enclosures. IMMEDIATE corrective action is
required to ensure proper enclosure operation. This condition report remains
active until the problem is corrected.
Complete the following procedure NOW to correct this problem.
1. Record all six characters of the condition report.
2. Reset the EMU.
3. Observe the EMU to ensure the error is corrected.
4. If resetting the EMU did not correct the problem, replace the EMU.
5. If unable to correct the problem, contact your HP authorized service
representative.
0.7.01.03 UNRECOVERABLE Condition
—
Power Supply Shutdown
This message only appears on the Command View EVA GUI to report a power
supply has already shut down. This message can be the result of the controller
shutdown command or an EMU or power supply initiated power shutdown.
This message cannot be displayed until after restoration of power. Therefore, there
is no corrective action required.
0.7.01.04 INFORMATION Condition
—
EMU Internal Data
The EMU is unable to collect data for the SCSI-3 Engineering Services (SES)
page. This condition report remains active for 15 seconds. The condition report
affects only internal EMU operations. There is no degradation of enclosure
operations.
The EMU initiates automatic recovery procedures.
If the problem is not automatically corrected after one minute, contact your HP
authorized service representative.