En.02 critical condition-high current, Backplane conditions, 10 noncritical condition-backplane nvram read – HP 3000 Enterprise Virtual Array User Manual
Page 184
EMU Generated Condition Reports
184
Enterprise Virtual Array 3000 User Guide
1.3.en.02 CRITICAL Condition
—
High Current
This condition report indicates that an element current has reached the high
current CRITICAL threshold. This condition report remains active until the
problem is corrected.
To correct this problem, record all six characters of the condition report, then
contact your HP authorized service representative.
Backplane Conditions
Note:
Backplane NVRAM errors usually occur during manufacture. At this time they
are identified and corrected. They rarely occur during normal operation.
The format of a backplane condition report is 8.2.01.ec, where:
■
8.2. is the backplane element type number
■
01. is the two-character backplane element number
■
ec is the error code
The only corrective action available for this error is to replace the drive enclosure.
8.2.01.10 NONCRITICAL Condition
—
Backplane NVRAM Read
An invalid NVRAM read occurred and an automatic recovery process has begun.
This condition report is active for 15 seconds.
If the automatic recovery process does not correct the problem, record all six
characters of the condition report, then contact your HP authorized service
representative.
8.2.01.11 NONCRITICAL Condition
—
Backplane NVRAM Write Failure
The system is unable to write data to the NVRAM. This problem prevents
communication between elements in the enclosure. This condition report is active
for 15 seconds.
To correct this problem, record all six characters of the condition report, then
contact your HP authorized service representative.