EMU Generated Condition Reports

184

Enterprise Virtual Array 3000 User Guide

1.3.en.02 CRITICAL Condition

High Current

This condition report indicates that an element current has reached the high
current CRITICAL threshold. This condition report remains active until the
problem is corrected.

To correct this problem, record all six characters of the condition report, then
contact your HP authorized service representative.

Backplane Conditions

Note:

Backplane NVRAM errors usually occur during manufacture. At this time they

are identified and corrected. They rarely occur during normal operation.

The format of a backplane condition report is 8.2.01.ec, where:

8.2. is the backplane element type number

01. is the two-character backplane element number

ec is the error code

The only corrective action available for this error is to replace the drive enclosure.

8.2.01.10 NONCRITICAL Condition

Backplane NVRAM Read

An invalid NVRAM read occurred and an automatic recovery process has begun.
This condition report is active for 15 seconds.

If the automatic recovery process does not correct the problem, record all six
characters of the condition report, then contact your HP authorized service
representative.

8.2.01.11 NONCRITICAL Condition

Backplane NVRAM Write Failure

The system is unable to write data to the NVRAM. This problem prevents
communication between elements in the enclosure. This condition report is active
for 15 seconds.

To correct this problem, record all six characters of the condition report, then
contact your HP authorized service representative.