Table 11 – HP 3000 Enterprise Virtual Array User Manual
Page 80
Storage System Hardware Components
80
Enterprise Virtual Array 3000 User Guide
Table 11: Nonoperational I/O Module LED Descriptions and Status Displays
Top LED
Power LED
Bottom LED
Descriptions
On
On
Off
■
Top Port—FC-AL signal detected.
■
Power—Present (After one minute the power LED
will be On constantly).
■
Bottom Port—No FC-AL signal detected.
Check transceiver and fiber cable connections.
Note:
This status is also displayed when connected
to a FC Loop switch.
Off
On
On
■
Top Port—No FC-AL signal detected.
Check transceiver and fiber cable connections.
■
Power—Present.
■
Bottom Port—FC-AL signal detected.
Flashing
On
On
■
Top Port—EMU detected possible transceiver
problem.
Check transceiver and fiber cable connections.
■
Power—Present.
■
Bottom Port—FC-AL signal detected.
On
On
Flashing
Top Port—FC-AL signal detected.
Power—Present.
Bottom Port—EMU detected possible transceiver
problem.
Check transceiver and fiber cable connections.
Note:
The EMU will not blink the bottom LED on its
own. It will only blink in response to a locate
command. You can blink each of the lights
independently for a locate and, if so, they may not
be in unison.
Off
Off
Off
■
No I/O module power.
■
I/O module is nonoperational.
■
Check power supplies. If power supplies are
operational, replace I/O module.