EMU Generated Condition Reports

186

Enterprise Virtual Array 3000 User Guide

8.7.en.01 CRITICAL Condition

I/O Module Unsupported

The I/O module Fibre Channel link speed is not supported by the backplane. This
error prevents the controller from establishing a link with enclosure drives and
eliminates the enclosure dual-loop capability. This condition report remains active
until the problem is corrected.

To correct this problem, record all six characters of the condition report, then
contact your HP authorized service representative.

8.7.en.02 CRITICAL Condition

I/O Module Communication

The I/O module is unable to communicate with the EMU.

Complete the following procedure to correct this problem:

1. Record all six characters of the condition report.

2. Contact your HP authorized service representative.

Note:

Multiple erroneous error messages indicating I2C bus errors, such as NVRAM

errors, blowers missing, and so forth, could indicate an EMU problem.

8.7.en.10 NONCRITICAL Condition

I/O Module NVRAM Read

An invalid NVRAM read occurred and automatic recover was initiated.

Complete the following procedure to correct this problem:

1. Record all six characters of the condition report.

2. Observe the I/O module status LEDs for an operational display.

3. Contact your HP authorized service representative.

8.7.en.11 NONCRITICAL Condition

I/O Module NVRAM Write

The system is unable to write data to the I/O module NVRAM.

Complete the following procedure to correct this problem:

1. Record all six characters of the condition report.

2. Observe the I/O module status LEDs for an operational display.

3. Contact your HP authorized service representative.