EMU Generated Condition Reports
182
Enterprise Virtual Array 3000 User Guide
0.F.en.03 CRITICAL Condition
—
Transceiver FC-AL Bus Fault
The system has detected an FC-AL bus fault involving a transceiver. This error
prevents the controller from transferring data on a loop and eliminates the
enclosure dual-loop capability
Complete the following procedure to correct this problem:
1. Record all six characters of the condition report.
2. Check all the transceivers and cables to ensure they are properly connected.
3. Check all the transceivers on the loop to ensure they are compatible with the
I/O module.
4. Contact your HP authorized service representative.
Voltage Sensor and Current Sensor Conditions
The format of these sensor condition reports is 1.2.en.ec for a voltage sensor, and
1.3.en.ec for a current sensor, where:
■
1.2. is the voltage sensor element type
■
1.3. is the current sensor element type number
■
en. is the sensor element number
■
ec is the error code
lists the location of the power supply voltage and current sensors.
Use Command View EVA to view the voltage and current error thresholds for both
+5 VDC and +12 VDC power supplies.
Table 45: Voltage and Current Sensor Locations
Sensor
Sensor Element Location
01.
Power Supply 1 +5 VDC
02.
Power Supply 1 +12 VDC
03.
Power Supply 2 +5 VDC
04.
Power Supply 2 +12 VDC