EMU Generated Condition Reports

182

Enterprise Virtual Array 3000 User Guide

0.F.en.03 CRITICAL Condition

Transceiver FC-AL Bus Fault

The system has detected an FC-AL bus fault involving a transceiver. This error
prevents the controller from transferring data on a loop and eliminates the
enclosure dual-loop capability

Complete the following procedure to correct this problem:

1. Record all six characters of the condition report.

2. Check all the transceivers and cables to ensure they are properly connected.

3. Check all the transceivers on the loop to ensure they are compatible with the

I/O module.

4. Contact your HP authorized service representative.

Voltage Sensor and Current Sensor Conditions

The format of these sensor condition reports is 1.2.en.ec for a voltage sensor, and
1.3.en.ec for a current sensor, where:

1.2. is the voltage sensor element type

1.3. is the current sensor element type number

en. is the sensor element number

ec is the error code

Table 45

lists the location of the power supply voltage and current sensors.

Use Command View EVA to view the voltage and current error thresholds for both
+5 VDC and +12 VDC power supplies.

Table 45: Voltage and Current Sensor Locations

Sensor

Sensor Element Location

01.

Power Supply 1 +5 VDC

02.

Power Supply 1 +12 VDC

03.

Power Supply 2 +5 VDC

04.

Power Supply 2 +12 VDC