EMU Generated Condition Reports

180

Enterprise Virtual Array 3000 User Guide

0.7.01.15 UNRECOVERABLE Condition

EMU Hardware Failure

The EMU is inoperative and must be replaced NOW! This condition report
remains active until the problem is corrected.

To correct this problem, record all six characters of the condition report, then
contact your HP authorized service representative.

0.7.01.16 INFORMATION Condition

EMU Internal ESI Data Corrupted

The EMU ESI data is corrupted. This condition does not affect any other element
and no action is required.

0.7.01.17 UNRECOVERABLE Condition

Power Shutdown Failure

The power supply did not respond to a controller, EMU, or power supply shut
down command. Shutting down the supply is required to prevent overheating.

Complete the following procedure to correct the problem:

1. Record all six characters of the condition report.

2. Move the power cord bail lock 1,

Figure 67

, to the left.

3. Disconnect the AC power cord 2 from the supply.

Figure 67: Disconnecting AC power

CXO7490A

2

3

1

4