beautypg.com

Correcting errors, Drive conditions, 43 assigned element type codes – HP 3000 Enterprise Virtual Array User Manual

Page 163

background image

EMU Generated Condition Reports

163

Enterprise Virtual Array 3000 User Guide

Correcting Errors

Correcting an error may require you to perform a specific set of actions. In some
cases, the only available corrective action is to replace the element.

Table 43

lists the element type codes assigned to the drive enclosure elements.

Elements that do not have an active condition report are shaded.

Drive Conditions

The format of a disk drive condition report is 0.1.en.ec, where:

0.1. is the disk drive element type number

en. is the two-character disk drive element

Table 43: Assigned Element Type Codes

Code

Element

0.1.

Disk Drives (see ““

Drive Conditions” on page 163

)

0.2.

Power Supplies (see

Figure 65

on page 167)

0.3.

Blowers (see

Figure 66

on page 169)

0.4.

Temperature Sensors (see

Table 44

on page 172)

0.6.

Audible Alarm

1

1. A shaded element does not generate a condition report. However, for any

error, you should record the error code. Then, implement the recommended

corrective action.

0.7.

EMU

0.C.

Controller OCP LCD

1

0.F.

Transceivers (see

Figure 68

on page 181)

1.0.

Language

1

1.1.

Communication Port

1

1.2.

Voltage Sensors (see

Table 45

on page 182)

1.3.

Current Sensors (see

Table 45

on page 182)

8.0.

Drive Enclosure

1

8.2.

Drive Enclosure Backplane

8.7.

I/O Modules (see

Figure 69

on page 185)

F.F.

Host