11 noncritical condition-emu nvram write failure, 13 unrecoverable condition-emu load failure – HP 3000 Enterprise Virtual Array User Manual
Page 178

EMU Generated Condition Reports
178
Enterprise Virtual Array 3000 User Guide
0.7.01.11 NONCRITICAL Condition
—
EMU NVRAM Write Failure
The EMU cannot write data to the NVRAM. This condition report remains active
until the problem is corrected.
Complete the following procedure to correct this problem:
1. Record all six characters of the condition report.
2. Reset the EMU.
3. Observe the EMU to ensure the error is corrected.
4. If resetting the EMU did not correct the problem, initialize the enclosure by:
a.
Removing power from the enclosure.
b.
Applying power to the enclosure.
5. Observe the EMU to ensure the error is corrected.
6. If initializing the enclosure did not correct the problem, contact your HP
authorized service representative.
0.7.01.12 NONCRITICAL Condition
—
EMU Cannot Read NVRAM Data
The EMU is unable to read data from the NVRAM. This condition report remains
active until the problem is corrected.
Complete the following procedure to correct this problem:
1. Record all six characters of the condition report.
2. Reset the EMU.
3. Observe the EMU to ensure the error is corrected.
4. If resetting the EMU did not correct the problem, initialize the enclosure by:
a.
Removing power from the enclosure.
b.
Applying power to the enclosure.
5. Observe the EMU to ensure the error is corrected.
6. If initializing the enclosure did not correct the problem, contact your HP
authorized service representative.
0.7.01.13 UNRECOVERABLE Condition
—
EMU Load Failure
The EMU Field Programmable Gate Array (FPGA) that controls the ESI bus
failed to load information required for EMU operation. This condition report
remains active until the problem is corrected.