EMU Generated Condition Reports

178

Enterprise Virtual Array 3000 User Guide

0.7.01.11 NONCRITICAL Condition

EMU NVRAM Write Failure

The EMU cannot write data to the NVRAM. This condition report remains active
until the problem is corrected.

Complete the following procedure to correct this problem:

1. Record all six characters of the condition report.

2. Reset the EMU.

3. Observe the EMU to ensure the error is corrected.

4. If resetting the EMU did not correct the problem, initialize the enclosure by:

a.

Removing power from the enclosure.

b.

Applying power to the enclosure.

5. Observe the EMU to ensure the error is corrected.

6. If initializing the enclosure did not correct the problem, contact your HP

authorized service representative.

0.7.01.12 NONCRITICAL Condition

EMU Cannot Read NVRAM Data

The EMU is unable to read data from the NVRAM. This condition report remains
active until the problem is corrected.

Complete the following procedure to correct this problem:

1. Record all six characters of the condition report.

2. Reset the EMU.

3. Observe the EMU to ensure the error is corrected.

4. If resetting the EMU did not correct the problem, initialize the enclosure by:

a.

Removing power from the enclosure.

b.

Applying power to the enclosure.

5. Observe the EMU to ensure the error is corrected.

6. If initializing the enclosure did not correct the problem, contact your HP

authorized service representative.

0.7.01.13 UNRECOVERABLE Condition

EMU Load Failure

The EMU Field Programmable Gate Array (FPGA) that controls the ESI bus
failed to load information required for EMU operation. This condition report
remains active until the problem is corrected.