HP 3000 Enterprise Virtual Array User Manual
Page 130
Storage System Hardware Components
130
Enterprise Virtual Array 3000 User Guide
PDU Assembly
The dual PDU assembly mounts in the lower rear of the rack. See
. This
assembly contains two PDUs: PDU 1
1
and PDU 2
7
. Each PDU has a 250-VAC,
30-A circuit breaker (
6
and
w
) and four IEC 320-C13 AC output power
receptacles (
2
through
5
, and
8
through
q
). The circuit breakers and AC
receptacles are accessible when the PDU assembly is in the upright position.
Figure 57: Enterprise Rack Dual PDU assembly major components
During normal operation, the hinged PDU assembly is in the upright position and
the rear door is closed.
1
PDU 1
2
PDU 1 AC receptacles
3
PDU 1 circuit breaker
4
PDU 2
5
PDU 2 AC receptacles
6
PDU 2 circuit breaker
Figure 56: Enterprise Rack Dual PDU assembly—top view
1
PDU 1
2
PDU 1 receptacle A
3
PDU 1 receptacle B
4
PDU 1 receptacle C
5
PDU 1 receptacle D
6
PDU 1 circuit breaker
7
PDU 2
8
PDU 2 receptacle A
9
PDU 2 receptacle B
-
PDU 2 receptacle C
q
PDU 2 receptacle D
w
PDU 2 circuit breaker
CXO7570A
1
4
2
3
5
6
CXO7571A
1
7
2
6
11
12
3
4
5
10
9
8
- StorageWorks MSL6000 Tape Library (61 pages)
- Лент-е накопители HP StoreEver DAT (64 pages)
- Лент-е накопители HP StoreEver DAT (50 pages)
- Linear Tape File System Software (25 pages)
- StoreEver Ultrium Tape Drives (78 pages)
- StoreEver Ultrium Tape Drives (76 pages)
- Linear Tape File System Software (20 pages)
- StoreEver Ultrium Tape Drives (61 pages)
- StoreEver TapeAssure Software (40 pages)
- StoreEver Ultrium Tape Drives (75 pages)
- StoreEver Ultrium Tape Drives (60 pages)
- Linear Tape File System Software (28 pages)
- 2600fx Optical Disk Drive (65 pages)
- Ленточный автозагрузчик HP StorageWorks DAT 72x10 (58 pages)
- StorageWorks 1000 Modular Smart Array (72 pages)
- StorageWorks 1000 Modular Smart Array (81 pages)
- StorageWorks 1500cs Modular Smart Array (48 pages)
- StorageWorks 1500cs Modular Smart Array (52 pages)
- StorageWorks 1500cs Modular Smart Array (71 pages)
- 2000fc Modular Smart Array (150 pages)
- Servidor de almacenamiento HP ProLiant DL585 G2 (152 pages)
- Sistemas de almacenamiento de red HP StorageWorks X3000 (152 pages)
- Software de HP StoreVirtual VSA (127 pages)
- Software de HP StoreVirtual VSA (85 pages)
- X500 Data Vault (331 pages)
- StorageWorks 1000i Virtual Library System (122 pages)
- XP Array Manager Software (101 pages)
- StorageWorks XP Remote Web Console Software (20 pages)
- 200 Storage Virtualization System (176 pages)
- StorageWorks MSA 2.8 SAN Switch (22 pages)
- StorageWorks MSA 2.8 SAN Switch (104 pages)
- StorageWorks MSA 2.8 SAN Switch (270 pages)
- StorageWorks MSA 2.8 SAN Switch (307 pages)
- StorageWorks All-in-One SB600c Storage Blade (78 pages)
- StorageWorks All-in-One SB600c Storage Blade (60 pages)
- StorageWorks All-in-One SB600c Storage Blade (72 pages)
- StorageWorks All-in-One SB600c Storage Blade (80 pages)
- ProLiant DL585 G2 Storage-Server (150 pages)
- Data Protector Express Basic-Software (83 pages)
- Data Protector Express Basic-Software (93 pages)
- ProLiant High Availability Storage Server (72 pages)
- ProLiant DL185 G5 Storage Server (174 pages)
- StorageWorks 2000fc G2 Modular Smart Array (76 pages)
- 2000I G2-Modular-Smart-Array (48 pages)
- P2000 G3 MSA Array Systems (58 pages)