Storage System Hardware Components

88

Enterprise Virtual Array 3000 User Guide

Should a blower be operating too slowly or stopped (a “blower failure”), internal
circuitry automatically causes the remaining operational blower to operate at a
higher speed. Simultaneously, the error condition is reported in several ways,
including the power supply LED, the audible alarm, the enclosure fault LEDs, and
the EMU alphanumeric display.

Should both blowers fail, the power supplies automatically shutdown.

Note:

The failure of a power supply +12.5 VDC circuit disables the associated blower.

Power Supply and Blower Status Reporting

The green status LED on the blower displays the status of both the power supply
and the blower. See

Table 15

for definitions of the LED displays.

Drive Enclosure EMU

The EMU provides increased protection against catastrophic failures. The EMU
communicates with the HSV Controller to detect conditions such as failed power
supplies, failed blowers, elevated temperatures, and external air sense faults.

The EMU for Fibre Channel-Arbitrated Loop (FC-AL) drive enclosures is fully
compliant with SCSI-3 Enclosure Services (SES), and mounts in the left rear bay
of a drive enclosure. See

1

,

Figure 40

.

Table 15: Power Supply and Blower Status LED Display

Blower Status LED

Description

On

Both the power supply and the blower are operational.

Flashing

The power supply or the blower locate function is active.

Off

The power supply or the blower is nonoperational. When

there is a blower problem, the other blower runs at a higher

speed.
Recommended corrective actions:
1. Check blower for proper operation. Replace if defective.
2. Check power supplies for proper operation. Replace if

defective.